This safety-rated digital input module provides sixteen channels for monitoring field contact status. The FC-SDI-1624 delivers SIL 3 certified performance for Honeywell Safety Manager and FSC platforms. Its dual-channel architecture ensures fail-safe operation in emergency shutdown and fire and gas systems. This unit performs comprehensive self-tests every cycle to guarantee input integrity.
Input Characteristics and Safety Ratings
The FC-SDI-1624 accepts dry contact inputs from switches, pushbuttons, and relay contacts. Each input supports both normally open and normally closed configurations with line monitoring. The module employs dual redundant processing paths for each input channel. Furthermore, the internal diagnostics detect open-wire, short-circuit, and stuck-on faults continuously.
| Parameter | Specification |
|---|---|
| Model Number | FC-SDI-1624 |
| Product Type | Safe Digital Input Module |
| Number of Channels | 16 safety-rated inputs |
| Input Type | Dry contact (NO/NC configurable) |
| Nominal Voltage | 24V DC (18-32V operating range) |
| Input Current | 5mA typical per channel |
| Line Monitoring | Open-wire and short-circuit detection |
| Safety Certification | SIL 3 (IEC 61508), PL e (ISO 13849) |
| Diagnostic Coverage | >99% for internal faults |
| Response Time | <10ms typical |
| Test Pulse Acceptance | 1ms to 50ms |
| Status Indicators | Red/Green LEDs per channel |
Physical Dimensions and Mounting Details
The FC-SDI-1624 measures 170mm wide, 130mm high, and 85mm deep. This safety module weighs approximately 1.0 kilograms and mounts directly onto standard DIN rails. The front panel provides a removable spring-clamp connector for all field wiring terminations. Each channel pair clearly marks its dual input terminals for proper connection. Additionally, the housing includes a locking mechanism that secures the module against vibration.
Energy Storage and Power Consumption
This safety module draws a maximum of 6.8 watts from the system backplane. The FC-SDI-1624 does not incorporate batteries or supercapacitors for energy storage. Instead, the module relies entirely on the Safety Manager backplane for its power supply. The efficient thermal design uses natural convection cooling for reliable operation. Consequently, this approach eliminates battery replacement while ensuring fail-safe performance.
System Integration and Diagnostic Features
The FC-SDI-1624 integrates seamlessly with Honeywell Safety Manager and FSC logic solvers. You can configure this module using Safety Builder engineering software for intuitive setup. The internal diagnostics continuously verify input switching integrity and communication health. Therefore, this safe digital input module provides dependable monitoring for critical safety instrumented functions.