This cable connects two Modicon Quantum backplanes for system expansion. It extends the X-bus between the primary rack and a secondary rack. Therefore, it increases total I/O capacity for large automation installations.
Technical Specifications of Schneider 140XCA71709
The Schneider 140XCA71709 measures 120.0 cm in total assembled length. Its cable weight equals approximately 0.25 kg for flexible routing within cabinets. Two 48-pin male connectors terminate each end of this expander cable. Additionally, the cable contains 48 individually shielded conductors for signal integrity.
| Parameter | Specification |
|---|---|
| Brand | Schneider Electric |
| Full Model | 140XCA71709 |
| Category | Backplane Expander Cable (X-Bus) |
| Total Length | 120.0 cm (47.24 inches / 3.94 feet) |
| Cable Weight | 0.25 kg (0.55 lbs) |
| Connector Type (Each End) | 1 x 48-pin Male (Standard Quantum Backplane) |
| Connector Material | Glass-Filled Polyester with Gold-Plated Pins |
| Number of Conductors | 48 Stranded Tinned Copper (28 AWG) |
| Conductor Shielding | Individual Foil Shielding per Conductor + Overall Braid |
| Impedance | 100 Ω (Differential Pairs) |
| Capacitance | 50 pF per Meter (Conductor to Shield) |
| Maximum Bend Radius | 5.0 cm (2.0 inches) for Static Installation |
| Insulation Material | PVC (Polyvinyl Chloride) |
| Outer Jacket Material | Gray PVC (Flame Retardant) |
| Jacket Outer Diameter | 1.2 cm (0.47 inches) |
| Connector Latches | Screw-Lock Type (M3 Threads) |
| Maximum Rack Separation | 100 cm (39.4 inches) between Backplanes |
| X-Bus Protocol | Proprietary Schneider Quantum Bus |
| Maximum Data Rate | 10 Mbps (Limited by Backplane, Not Cable) |
| On-Board Components | None (Passive Copper Cable Assembly) |
| Energy Storage | None (Passive Component) |
| Maximum Operating Voltage | 30 VDC (Signal Lines) |
| Maximum Current per Pin | 1 A (All 48 Pins) |
| Operating Temperature | 0°C to +60°C (32°F to 140°F) |
| Storage Temperature | -25°C to +85°C (-13°F to 185°F) |
| Flammability Rating | UL 94 V-0 (Connectors) + VW-1 (Cable Jacket) |
Cable Construction and Signal Isolation
The Schneider 140XCA71709 uses 48 individually shielded conductors for robust signal transmission. Foil shielding on each wire prevents crosstalk between adjacent X-bus signals. An overall braided shield provides additional protection against external electromagnetic interference. Consequently, this cable maintains data integrity even in electrically noisy industrial environments.
Physical Layout and Rack Expansion
You will find screw-lock connectors at both ends of this expander cable. These connectors secure firmly to the Quantum backplane X-bus ports. The cable allows up to 100 cm of separation between two backplanes. Thus, you can place secondary I/O racks remotely from the main CPU rack.
Installation and Routing Guidelines
This cable requires a minimum bend radius of 5.0 cm for safe installation. Do not kink or crush the cable during cabinet routing. Secure the cable using plastic ties at regular intervals. The gray PVC jacket resists oil, moisture, and industrial chemicals. Therefore, the Schneider 140XCA71709 suits harsh factory floor environments.