Why This DC Power Connect Board Distributes Reliable DC Power
The GE DS200PCCAG5A DS200PCCAG5ACB distributes DC power across Mark V turbine racks. This board connects the main power supply to multiple downstream cards. It provides overcurrent protection for each individual output channel. For this reason, the GE DS200PCCAG5A DS200PCCAG5ACB prevents a single fault from shutting down the entire system. It also simplifies power wiring inside crowded cabinets.
Technical Specifications of the Board
We engineer this GE DS200PCCAG5A DS200PCCAG5ACB for robust power distribution. It accepts a 125V DC input supply with ±15% tolerance. The board features five independent output channels with fusing. Each channel includes LED indicators for status monitoring. On‑board capacitors store energy for momentary load changes.
| Specification | Value | Additional Notes |
|---|---|---|
| Full Model | GE DS200PCCAG5A DS200PCCAG5ACB | DC Power Connect Board |
| Input Voltage | 125V DC ±15% | Standard Mark V DC bus |
| Output Channels | Five isolated outputs | For distributing to control cards |
| Overcurrent Protection | Fuse per channel | 2A slow‑blow fuses |
| Status Indication | Five LED indicators | One per output channel |
| Energy Storage | Electrolytic capacitor bank | 1200µF total capacitance |
| Current Rating | 8A maximum input | Total input current limit |
| Dimensions | 200mm x 120mm x 60mm | Fits Mark V power racks |
| Weight | 0.68 kg (approximately) | Robust construction for high power |
| Interface Type | Backplane connector + screw terminals | Heavy‑duty copper terminals |
| Component Count | 32 discrete components | Fuses, capacitors, resistors, LEDs |
Hardware Architecture and Power Flow
The GE DS200PCCAG5A DS200PCCAG5ACB includes a bus bar for input power distribution. This bus bar connects directly to the external 125V DC supply. Moving to output side, five fuses protect each downstream card individually. The board also filters incoming power using capacitor banks. Moreover, the G5ACB revision adds enhanced thermal management. This improvement allows higher ambient temperature operation.
Installation and Replacement Guidelines
You must de‑energize the entire cabinet before removing this board. Remove the GE DS200PCCAG5A DS200PCCAG5ACB from its rack slot carefully. Then insert the replacement board into the exact same slot position. Verify all backplane pins align correctly with the connector. Skipping this check may cause improper power distribution. Additionally, test each output channel voltage after completing the installation.
MeloAuto-Trusted PLC & DCS Parts Supplier















WeChat
Scan the QR Code with wechat