This GE DS200ITXSG1A DS200ITXSG1ABB Inverter Snubber Board protects inverter IGBT modules from voltage transients. The board connects directly across each IGBT in the inverter bridge circuit. You will find this component in many GE drive and excitation systems. The DS200ITXSG1ABB variant includes the standard factory configuration without conformal coating.
Technical Specifications
| Parameter | Specification |
|---|---|
| Full Model | GE DS200ITXSG1A DS200ITXSG1ABB Inverter Snubber Board |
| Category | Inverter Snubber Board |
| Number of Channels | 6 Independent Snubber Circuits |
| Resistor Value | 12 Ω, 50W Non-Inductive per Channel |
| Capacitor Value | 0.47 µF, 1200V Polypropylene per Channel |
| Peak Voltage Rating | 1200 V |
| dv/dt Suppression | 700 V/µs Maximum |
| Dimensions (H x W) | 200 mm x 140 mm |
| Weight | Approximately 0.75 kg |
| Connectors | 6 x Quick-Disconnect Terminals |
| Component Count | 12 Resistors, 6 Capacitors, 6 Diodes |
| Energy Storage | 0.47 µF per Channel (Total 2.82 µF) |
Transient Suppression and Protection Features
The GE DS200ITXSG1A DS200ITXSG1ABB Inverter Snubber Board limits voltage spikes across each IGBT during turn-off. Each channel combines a 12 Ω resistor with a 0.47 µF capacitor. This RC network absorbs energy from parasitic inductances in the DC bus. Furthermore, the card includes a fast recovery diode in series with each resistor. Consequently, your IGBT modules operate safely under harsh switching conditions.
Installation and Connection Steps
Mount this GE DS200ITXSG1A DS200ITXSG1ABB Inverter Snubber Board near the IGBT bridge in the drive cabinet. First, connect each channel’s terminals across one IGBT’s collector and emitter. After that, verify all six connections match the correct phase assignments. Then, secure the board using four M3 mounting screws. Finally, check that no terminals touch adjacent circuits before powering up.
Energy Discharge and Safety Notice
This GE DS200ITXSG1A DS200ITXSG1ABB Inverter Snubber Board stores energy in its six capacitors. Therefore, you must wait at least one minute after power removal. The capacitors discharge through their series resistors naturally. Never short the terminals to discharge them faster.
Status Indication and Diagnostics
This snubber board has no active indicators or LEDs. However, you can test each RC network with an LCR meter. A failed capacitor typically shows as a short or open circuit. A burned resistor indicates excessive switching energy in that phase. The series diode may fail short under extreme reverse voltage conditions.