This GE DS200CDBAG1B DS200CDBAG1BCB Contactor Driver Board controls high-power contactors and solenoids directly. The board receives low-voltage logic signals and switches high-current loads safely. You will find this component in Mark V turbine control systems worldwide. The DS200CDBAG1BCB variant includes a rugged conformal coating for humid environments.
Technical Specifications
| Parameter | Specification |
|---|---|
| Full Model | GE DS200CDBAG1B DS200CDBAG1BCB Contactor Driver Board |
| Category | Contactor Driver Board |
| Driver Channels | 8 Independent Outputs |
| Output Voltage | 125 VDC or 250 VDC (Field Selectable) |
| Output Current | 5A Continuous, 15A Inrush per Channel |
| Input Logic | 5V or 24V DC, Opto-Isolated |
| Response Time | Less than 5 milliseconds |
| Dimensions (H x W) | 200 mm x 130 mm |
| Weight | Approximately 0.75 kg |
| Connectors | 2 x Terminal Blocks, 1 x 20-Pin Header |
| Component Count | 98 Discrete Components |
| Energy Storage | 8 x 100 µF Snubber Capacitors |
Switching Control and Protection Features
The GE DS200CDBAG1B DS200CDBAG1BCB Contactor Driver Board uses MOSFET switches for each output channel. Each channel includes a flyback diode for inductive load protection. The board provides status feedback for weld detection on each contactor. Furthermore, it includes programmable inrush current limiting for each output. Consequently, you can drive large solenoids without external suppression circuits.
Installation and Connection Steps
Mount this GE DS200CDBAG1B DS200CDBAG1BCB Contactor Driver Board in any Mark V rack slot. First, connect the DC supply voltage to the TB1 power terminals. After that, wire each contactor coil to the corresponding TB2 output. Then, attach the logic input cable to the 20-pin header. Finally, test each channel individually before enabling automatic control.
Energy Discharge and Safety Notice
This GE DS200CDBAG1B DS200CDBAG1BCB Contactor Driver Board stores energy in its snubber capacitors. Therefore, you must wait at least one minute after power removal. The eight capacitors discharge through internal bleeder resistors during this time. Never disconnect a contactor while the output remains active.
Status Indication and Diagnostics
Eight green LEDs show the active status of each driver channel clearly. A red LED illuminates when the board detects a welded contactor fault. A yellow LED flashes during the power-up self-test routine. These indicators help technicians troubleshoot contactor issues without special tools.
MeloAuto-Trusted PLC & DCS Parts Supplier















WeChat
Scan the QR Code with wechat