The ICS Triplex T9831 reads field input signals inside Trusted and Regent safety systems. Engineers select this unit when discrete and analog inputs must share one compact platform. Consequently, the module delivers reliable data acquisition across redundant processing lanes.
Physical Dimensions and Weight Data
Cabinet space often limits how technicians arrange input hardware inside safety racks. Therefore, the ICS Triplex T9831 keeps a compact profile while preserving full channel density. It weighs roughly 1.2 kg and fits a standard 6U rack slot. Additionally, its dimensions measure 233 mm by 160 mm by 40 mm.
Interfaces and Connectivity Features
Reliable signal acquisition depends on secure terminations at every input point. The ICS Triplex T9831 provides dual redundant backplane interfaces for critical signal paths. Furthermore, front-panel LEDs let technicians verify channel and fault status instantly. Hot-swap support allows replacements without interrupting the monitored process.
Component Count and Energy Storage
Internal architecture shapes both diagnostic coverage and service life. The ICS Triplex T9831 carries more than 350 discrete components across separate processing lanes. Moreover, a lithium battery retains configuration data for up to 90 days. This storage protects non-volatile memory whenever plant power drops.
Key Technical Specifications
| Parameter | Specification |
|---|---|
| Module Type | Input module |
| Dimensions | 233 × 160 × 40 mm |
| Weight | 1.2 kg |
| Rack Size | 6U |
| Backplane Interfaces | Dual redundant |
| Input Channels | 16 inputs |
| Component Count | 350+ discrete parts |
| Energy Storage | Lithium battery, 90-day retention |
| Hot-Swap Support | Yes |
| Operating Temperature | 0°C to 60°C |
| Input Voltage Range | 18–32 VDC |
| Isolation Voltage | 500 VDC |
| Diagnostic Coverage | Over 99% |
Input Performance and Compliance
Fast sampling directly influences overall safety loop response times. The ICS Triplex T9831 detects input state changes within 10 ms. Meanwhile, isolation voltage reaches 500 VDC between field wiring and internal circuits. Diagnostic coverage exceeds 99%, which strengthens safe failure detection.
Industrial sites also demand strict safety certifications before deployment. The module complies with IEC 61508 SIL 3 functional safety requirements. In addition, it meets CE and UL standards for electromagnetic compatibility. These credentials support dependable operation in harsh plant environments.
MeloAuto-Trusted PLC & DCS Parts Supplier