Over 50,000 Brand New, 100% Genuine PLC/PAC & DCS Products!

Honeywell C200/C300 Series/Honeywell/

Honeywell 51301877-100 RTD Multiplexer Logic PCB Module

Brand:Honeywell
Part Number:51301877-100
Product:RTD Multiplexer Logic PCB Module
Origin:United States
Payment: T/T, Western Union
Price: USD 99
Dimensions: 180 x 70 x 55 mm
Weight: 0.5 kg 
Warranty: 12 months

  • Product Details
  • Datasheet

The 51301877-100 RTD multiplexer logic PCB module expands temperature sensing capacity inside Honeywell control systems. Engineers select this board for its compact layout and stable channel switching behavior. Furthermore, the module handles multiple RTD inputs through a single controller slot.

Key Technical Specifications

The 51301877-100 measures approximately 20.3 cm in length and 15.2 cm in width. Moreover, it weighs roughly 0.3 kg, which suits standard card-rack mounting. The board connects to field RTDs through a multipin terminal interface and links to the controller via the backplane bus.

Parameter Specification
Brand Honeywell
Model 51301877-100
Category RTD Multiplexer Logic PCB Module
Dimensions ~20.3 × 15.2 cm
Weight ~0.3 kg
Input Channels 16 RTD inputs
Interface Multipin terminal block, backplane bus connector
Energy Storage Onboard decoupling capacitors
Operating Temperature 0 °C to 60 °C

Interface and Switching Details

Multiplexing logic scans each RTD channel in sequence and forwards readings to the controller. The multipin terminal block accepts standard three-wire RTD connections. Additionally, onboard relays isolate inactive channels and reduce measurement crosstalk. Channel scanning timing follows the controller clock for consistent sampling intervals.

Component Count and Energy Storage

The 51301877-100 contains roughly 160 discrete components on a single PCB assembly. Consequently, the design concentrates switching logic and minimizes external wiring. Onboard capacitors store enough energy to ride through brief supply dips. Therefore, the board keeps channel readings stable during transient disturbances.

Installation and Commissioning

Technicians seat the board in the rack and secure the retaining screws. You should verify terminal torque values before energizing the system. Afterward, run a channel scan test through the controller diagnostics. Finally, record baseline resistance readings for future maintenance comparisons.