Key Technical Specifications
This GE DS200DMCBG1A DS200DMCBG1ABB board operates from a 24V DC power supply. It runs dual redundant processors at 100 MHz clock speed. The unit measures 24 cm in length, 18 cm in width, and 4.5 cm in height. Its total weight reaches 0.85 kg without any packaging materials.
The GE DS200DMCBG1A DS200DMCBG1ABB includes two independent CPU cores for fault tolerance. Additionally, it features one VME backplane connector for system integration. A single 4-pin terminal block connects the DC power input. The board contains 2 processors, 4 memory banks, 2 FPGAs, 8 voltage regulators, 6 status LEDs, and 32 resistors.
| Parameter | Value |
|---|---|
| Power Supply | 24V DC ±10%, 600mA |
| Processor Type | Dual 32-bit RISC |
| Clock Frequency | 100 MHz each |
| RAM | 16 MB (8 MB per processor) |
| Flash Memory | 4 MB (2 MB per processor) |
| Dimensions (L x W x H) | 24 cm x 18 cm x 4.5 cm |
| Weight | 0.85 kg |
| Backplane Interface | VME64 P1/P2 |
| Power Connector | 4-pin terminal block |
| Status LEDs | 6 units (Power, Run, Fault, Sync, A/B) |
| Processors | 2 units (redundant) |
| Memory Banks | 4 units |
| FPGAs | 2 units (configuration logic) |
| Voltage Regulators | 8 units |
| Watchdog Timers | 2 units |
| Resistors | 32 units |
| Capacitors | 24 units |
| Energy Storage | 470 µF at 35V |
GE DS200DMCBG1A DS200DMCBG1ABB stores energy using two large electrolytic capacitors. Together, they provide 470 µF at 35V rating for processor hold-up. This energy storage maintains operation during 30 millisecond power interruptions. Therefore, the board prevents data corruption during brief voltage sags.
Design and Integration
Both the GE DS200DMCBG1A and DS200DMCBG1ABB versions share identical dual-processor topology. These boards use eight-layer PCB construction with controlled impedance traces for high-speed signals. Consequently, the GE DS200DMCBG1A DS200DMCBG1ABB operates reliably from 0°C to +55°C ambient temperature.
For installation, you need M3 screws for the four mounting holes. The board draws 500 mA typical current from the 24V DC supply. The dual processors run in lockstep mode for fault detection. We recommend using forced air cooling for high-temperature environments.
Practical Application
This DOS DUP processor board executes real-time control algorithms for turbine and generator systems. It monitors inputs from field sensors and computes output commands. The GE DS200DMCBG1A DS200DMCBG1ABB switches to the redundant processor automatically upon fault detection. Therefore, it provides high-availability computing for critical industrial applications.
MeloAuto-Trusted PLC & DCS Parts Supplier















WeChat
Scan the QR Code with wechat