The GE IS200VTCCH1C board measures temperature directly from thermocouple sensors. This thermocouple input PCB also carries the revision code IS200VTCCH1CBD . It accepts multiple thermocouple types for exhaust and bearing monitoring. The board provides accurate temperature data for turbine protection systems.
Technical Specifications of GE IS200VTCCH1C IS200VTCCH1CBD
| Parameter | Specification |
|---|---|
| Manufacturer | General Electric (GE) |
| Series | Mark VI Speedtronic |
| Full Model | GE IS200VTCCH1C (IS200VTCCH1CBD) |
| Board Dimensions | 26.04 cm x 2.54 cm x 18.73 cm |
| Weight | Approximately 0.34 kg |
| Input Channels | 8 (Differential) |
| Thermocouple Types | J, K, T, E, R, S, B |
| Resolution | 24-bit (Typical) |
| Accuracy | ±0.1% of reading |
| Cold Junction Compensation | Built-in sensor |
| Power Dissipation | 6 W (Maximum) |
Component Count and Board Construction
The GE IS200VTCCH1C board contains over 200 discrete components. You will find multiple high-precision operational amplifiers for signal conditioning. Furthermore, the board includes a dedicated cold junction compensation sensor. The assembly also features optical isolation for each input channel. Each channel uses a 24-bit ADC for high resolution.
Interfaces, Energy Storage, and Signal Processing
The IS200VTCCH1CBD revision provides a front-face terminal block for thermocouple wiring. Moreover, the board uses capacitors for input filter networks. These capacitors store minimal energy but reject 60 Hz noise effectively. Each channel includes a dedicated analog-to-digital converter. The cold junction sensor maintains accurate reference temperature.
Functional Logic and Application Context
This Mark VI board samples all eight thermocouple inputs at 10 Hz continuously. It then converts microvolt signals into linearized temperature readings. The GE IS200VTCCH1C performs automatic cold junction compensation for each channel. Additionally, it detects open thermocouple conditions and reports sensor failures. Consequently, the board ensures reliable temperature monitoring in harsh environments.
Channel Configuration and Burnout Detection
You can configure each channel for a specific thermocouple type independently. The board provides built-in burnout detection for broken sensor wires. Furthermore, the IS200VTCCH1CBD applies software linearization tables for accuracy. This linearization covers the full temperature range of each sensor type. The board also includes averaging filters for noise reduction on critical channels.
Installation and Environmental Limits
You must power down the VME rack before inserting this thermocouple board. The operating temperature range spans 0°C to 60°C . Furthermore, the board provides 1500 V isolation between inputs and logic. Always verify the IS200VTCCH1CBD channel configuration before connecting sensors. Use proper thermocouple extension wire for accurate readings.
MeloAuto-Trusted PLC & DCS Parts Supplier

















WeChat