The Honeywell 51400955-100 Process Network Interface Board connects controller racks to plant-wide process networks. This card combines a dedicated network controller with onboard buffering and a rugged backplane interface. System integrators rely on it for deterministic data exchange between controllers and supervisory systems. Consequently, operators gain consistent network throughput during high-demand process cycles.
Technical Specifications
The board measures approximately 170 mm in length and 105 mm in width, matching standard rack slots. It weighs roughly 0.31 kg, so one technician can seat it without lifting aids. A 44-pin edge connector carries data and power between the board and the backplane. The card draws 5 VDC at a nominal 1.1 A and houses about 88 components. Network throughput reaches 10 Mbps across two independent ports. Onboard buffering holds 1 MB of packet data for burst handling. In addition, a 0.2 F supercapacitor stores backup energy during brief power interruptions.
| Parameter | Specification |
|---|---|
| Part Number | 51400955-100 |
| Category | Process Network Interface Board |
| Length | ~170 mm |
| Width | ~105 mm |
| Weight | ~0.31 kg |
| Connector | 44-pin edge connector |
| Supply Voltage | 5 VDC |
| Current Draw | ~1.1 A |
| Network Throughput | 10 Mbps |
| Ports | 2 independent |
| Buffer Memory | 1 MB |
| Component Count | ~88 parts |
| Energy Storage | 0.2 F supercapacitor |
Network Handling and Integration
The 51400955-100 manages packet routing and error checking across two independent network ports. Because the onboard buffer absorbs traffic bursts, message loss stays minimal during peak demand. The 10 Mbps throughput supports deterministic exchange between controllers and supervisory stations. Meanwhile, the dual-port design allows redundant paths for critical process loops. A move to plant-wide networking becomes practical, since the board fits existing rack footprints.
Installation and Operating Limits
This board operates within 0–60 °C, which suits control cabinets and plant floor enclosures. It draws power from the 5 VDC backplane bus and needs no separate supply wiring. The 44-pin connector seats firmly, so vibration cannot interrupt network traffic. Therefore, commissioning and spare swaps take only minutes. For plant-wide network rollouts, the 51400955-100 delivers dependable data bridging with minimal engineering effort.
MeloAuto-Trusted PLC & DCS Parts Supplier


















WeChat
Scan the QR Code with wechat