The Foxboro P0972VA ATS Processor Module is designed to deliver reliable processing power for industrial automation systems. This module comes in a single-width configuration, and its redundant version consists of two modules connected by a redundant connector. It integrates seamlessly with Foxboro I/A Series systems, ensuring high availability and robust performance.
Key Features
- Single and Redundant Configurations: The P0972VA module is available in both single and redundant versions. The redundant version includes two modules and a redundant connector to ensure continuous operation.
- Ethernet Connectivity: This module supports both copper and fiber optic cables for Ethernet connections, offering flexibility in system integration.
- Flexible Mounting Options: Mount the module in either a 1×8 or 2×8 mounting structure, depending on your system requirements. The redundant version requires adjacent slots to accommodate the redundant connector.
- Compact Design: Despite its high performance, the module maintains a compact size suitable for tight industrial environments.
- High Capacity: The P0972VA supports high-speed Ethernet communication, ensuring fast data transfer between connected systems.
Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer | Foxboro |
| Model Number | P0972VA |
| Product Type | ATS Processor Module |
| Configuration | Single-width, redundant version available |
| Weight | 1.7 kg (3.75 lb) for single module |
| Mounting Options | 1×8 Mounting Structure, 2×8 Mounting Structure |
| Dimensions (Single-width Module) | Height: 228 mm (8.97 in) |
| Width: 34.3 mm (1.35 in) | |
| Depth: 447 mm (17.6 in) | |
| Redundant Connector Part Number | P0926DF |
| Ethernet Cabling (Fiber Optic) | Multi-mode fiber (62.5/125 µm), LC connectors |
| Ethernet Cabling (Copper) | Shielded copper cable, RJ-45 connectors |
| Maximum Cable Length (Fiber Optic) | 2 km (6560 ft) total from switch to ATS |
| Maximum Cable Length (Copper) | 100 m (330 ft) total from switch to ATS |
Cabling Options
- Fiber Optic Cable:
- Connectors: Two ceramic-type LC connectors with clips at each end.
- Cable Material: Multi-mode fiber (MMF), 62.5/125 µm.
- Cable Lengths: 3.0 m (9.9 ft), 15 m (49.5 ft), 50 m (165 ft). For lengths over 50 m, user-supplied cable is required.
- Maximum Length: 2 km (6560 ft) total from Ethernet switch to ATS.
- Copper Cable:
- Connectors: RJ-45 connectors.
- Cable Material: Shielded copper cable.
- Cable Lengths: 0.5 m (1.6 ft), 3.0 m (9.9 ft), 15 m (49.5 ft), 50 m (165 ft), 100 m (330 ft).
- Maximum Length: 100 m (330 ft) total from Ethernet switch to ATS.
Environmental and Operational Specifications
- Operating Temperature: -40°C to +70°C (-40°F to +158°F).
- Relative Humidity: 5 to 95% (non-condensing).
- Contamination: Suitable for use in harsh industrial environments as per ISA Standard S71.04, based on exposure testing according to EIA Standard 364-65, Class III.
- Vibration: 0.75 g (5 to 200 Hz), ensuring durability in challenging environments.
Applications
The Foxboro P0972VA ATS Processor Module is ideal for industrial automation systems requiring high reliability, redundancy, and fast communication. It is perfect for process control, remote monitoring, and industrial networking, ensuring a robust infrastructure for automation and control tasks.