Over 50,000 Brand New, 100% Genuine PLC/PAC & DCS Products!

Emerson/

Emerson 12P5547X032 KL3106X1-BA1 I.S. RTD and Resistance Input CHARM

Brand:Emerson
Part Number:12P5547X032 KL3106X1-BA1
Product:I.S. RTD and Resistance Input CHARM
Origin:Thailand
Payment: T/T, Western Union
Price: USD 99
Dimensions:175 x 140 x 35 mm
Weight:0.65 kg
Warranty: 12 months

  • Product Details
  • Datasheet

The 12P5547X032 KL3106X1-BA1 operates as an intrinsically safe RTD and resistance input module within Emerson DeltaV systems. Engineers select this CHARM for temperature monitoring in hazardous process areas. Moreover, it carries certification for use in Zone 1 and Division 1 environments.

Physical Dimensions and Weight

This module measures approximately 12.0 cm in height and 2.5 cm in width. Additionally, it weighs roughly 0.15 kg, which suits dense CHARM carrier configurations. The slim profile lets technicians populate many slots within a single carrier.

Input Channels and Interface Details

The 12P5547X032 KL3106X1-BA1 supports one RTD or resistance input channel per module. Specifically, it accepts 2-wire, 3-wire, and 4-wire RTD configurations for flexible field wiring. Furthermore, the module connects to the CHARM carrier through a plug-in backplane interface. This interface carries power and digital communication to the DeltaV controller.

Component Architecture and Energy Storage

The design combines a precision A/D converter with intrinsic safety barrier circuitry on one PCB. In addition, onboard capacitive storage maintains measurement stability during brief supply dips. Specifically, this energy storage sustains diagnostic reporting for up to 20 milliseconds after power loss.

Key Technical Parameters

Parameter Specification
Module Type I.S. RTD and Resistance Input CHARM
Input Channels 1 per module
RTD Wiring 2-wire, 3-wire, 4-wire
Dimensions (H × W) 12.0 cm × 2.5 cm
Weight 0.15 kg
Connector Type Plug-in backplane / screw terminal
Energy Storage Capacitive, 20 ms ride-through
Isolation Galvanic per channel
Hazardous Area Rating Intrinsically safe, Zone 1 / Div 1
Operating Temperature 0 °C to 60 °C

Diagnostic and Fault-Tolerant Behavior

Each channel performs open-sensor and short-circuit checks before the module reports to the controller. Therefore, the 12P5547X032 KL3106X1-BA1 detects wiring degradation and sensor drift early. As a result, maintenance teams schedule calibration before measurement accuracy affects the process loop.

Integration within DeltaV Architectures

The module operates alongside companion CHARM modules on the same carrier assembly. Meanwhile, hot-swap capability lets technicians replace a faulty unit without stopping the process. Consequently, plant operators maintain continuous monitoring throughout routine maintenance windows.