The IPESW11 from ABB Bailey functions as a dedicated power entry switch assembly. It provides a centralized location for main power connection and system isolation. This component incorporates both power input terminals and a manual disconnect mechanism. Engineers rely on its integrated design for safe equipment servicing procedures.
Technical Specifications & Hardware Details
| Specification | Detail |
|---|---|
| Manufacturer | ABB Bailey |
| Model Number | IPESW11 |
| Category | Power Entry Switch |
| Weight | Approximately 0.55 kg (1.21 lbs) |
| Dimensions (H x W x D) | 6.5 in x 4.2 in x 3.8 in (165 mm x 107 mm x 97 mm) |
| Switch Rating | 10 A at 250 VAC |
| Termination Points | 6 screw-type terminal positions |
| Interface | Line input, load output, and chassis ground terminals |
| Component Count | Single-unit assembly with rotary switch and terminal block |
| Energy Storage | None (Passive switching only) |
Power Entry and Isolation Capabilities
The IPESW11 accepts incoming AC power through its line-side terminal block. Its manual rotary switch provides positive isolation for maintenance activities. You can lock this switch in the OFF position for equipment safety compliance. Furthermore, the design includes integrated strain relief for incoming power cables. This strain relief prevents accidental disconnection during cabinet operation.
Physical Construction and Mounting Layout
This power entry assembly features a compact construction suited for panel mounting. Its housing provides clear labeling for line, load, and ground connections. The IPESW11 mounts directly to cabinet enclosures using standard hardware. You can install this unit without removing existing power distribution components. The assembly’s design simplifies both initial installation and field replacement.
System Integration and Safety Features
The module serves as the primary power entry point for Bailey system cabinets. It distributes power to internal power supplies and distribution units. The IPESW11 works alongside circuit breakers and fuses for complete overcurrent protection. For similar industrial applications, static trip units and protective relays use comparable power switching principles. However, this power entry switch specifically addresses system isolation requirements within the Bailey ecosystem. Facilities rely on it for safe equipment access during maintenance and troubleshooting.