Overview
The ProSoft MVI69-MCM is a Modbus Master/Slave Network Interface Module designed for CompactLogix™ and MicroLogix™ 1500 LRP controllers. This module enables seamless integration between Rockwell Automation® PLCs and Modbus-compatible devices, including Modicon® PLCs and third-party industrial equipment.
The MVI69-MCM supports Modbus RTU and ASCII protocols, making it suitable for SCADA, field device interfacing, and process automation applications. It features a high-speed data transfer rate, optimized polling mechanisms, and flexible floating-point data movement.
Key Features
- High-Speed CompactLogix Integration
- Licensed 1769 backplane technology for fast data exchange
- Recognized as an I/O module for direct processor access
- Compatible with CompactLogix and MicroLogix 1500 LRP
- Modbus Master & Slave Functionality
- Can be configured as Master or Slave on two independent application ports
- Supports Modbus RTU and ASCII
- Floating-point data movement with support for Enron and Daniel® implementations
- Optimized Polling & Error Handling
- Up to 100 Master commands per port
- Intelligent polling reduces delays due to communication issues
- Error codes and diagnostics for troubleshooting
- ProSoft Configuration Builder (PCB) Software
- User-friendly drag-and-drop interface
- Supports real-time diagnostics
- Sample configuration and ladder logic files included
- Reliable & Durable
- Optical isolation (500V) between module and backplane
- Three-year warranty
- Free lifetime technical support
Technical Specifications
General Specifications
Specification |
Details |
Brand |
ProSoft Technology |
Part Number |
MVI69-MCM |
Backplane Compatibility |
1769 CompactLogix/MicroLogix |
Power Supply Distance Rating |
2 (L43 & L45 installations in first two slots) |
Current Load |
800 mA max @ 5V DC |
Configuration |
Sample ladder logic and configuration files included |
Supported Controllers |
CompactLogix & MicroLogix 1500 LRP (except 1769-L23E-QBFC1B, 1769-L16x, 1769-L18x) |
Modbus Master/Slave Communication
Parameter |
Details |
Baud Rate |
110 to 115K baud |
Data Bits |
7 or 8 bits |
Stop Bits |
1 or 2 |
Parity |
None, Even, Odd |
Modbus Modes |
RTU (CRC-16) & ASCII (LRC error checking) |
Floating Point Support |
Enron, Daniel®, and other formats |
Supported Function Codes |
Read Coils, Read Input Registers, Write Holding Registers, Diagnostics, Mask Write, etc. |
Master Capabilities |
Up to 100 commands per port, optimized polling, configurable command execution |
Slave Capabilities |
Full data interaction, Node ID: 1-247, error codes and status monitoring |
Hardware Specifications
Specification |
Details |
Module Type |
Single-slot, 1769 standard |
Operating Temperature |
0°C to 60°C (32°F to 140°F) |
Storage Temperature |
-40°C to 85°C (-40°F to 185°F) |
Humidity |
5% to 95% (non-condensing) |
LED Indicators |
Battery, Module Status, Serial Activity, Configuration Port Activity |
CFG Port |
RS-232 (RJ45 to DB-9F cable included) |
Application Ports (P1, P2) |
RS-232/RS-485/RS-422 (jumper selectable) |
Isolation |
500V Optical Isolation from Backplane |
Included Accessories |
RJ45 to DB-9M cables, 6-foot RS-232 configuration cable |
Applications
- SCADA and HMI Integration
- Connects CompactLogix and MicroLogix 1500 to Modbus RTU/ASCII field devices
- Ideal for process automation and industrial control systems
- Modbus-Based Device Communication
- Enables communication between Rockwell Automation PLCs and Modicon PLCs
- Supports integration with flow meters, sensors, and control equipment
- Process Control & Monitoring
- Real-time data exchange for distributed control systems (DCS)
- Error detection and status monitoring for improved reliability
- Remote and Distributed Automation
- Allows remote control and monitoring of industrial equipment
- Compatible with legacy Modbus devices
WeChat